user_mobilelogo

A-DQ(ZN)B2Y

fiber_optic_cable_02_image_1151820638_1329553220


Specifications

xxxxxx1
Fiber Optics A-DQ(ZN)B2Y

Application:

Outdoor Dielectric Rodent Protected

Cable Design   Technical Data Specified value

Acceptance

criteria

Numbers of fibers:

4, 6, 8,  12

Tensile strength (short term-insallation): 1000 N Δα< 0.05 dB reversible, fiber stain < 0.33%
Number of loose tubes: 1 Tensile strength (long term-operation): 350 N Δα< 0.05 dB reversible, no fiber strain
Number od fibers per tube: 4, 6, 8, 12 Crush resistance (short term):  2500 N/10cm Δα< 0.05 dB reversible, no damage
Outer seath thikness (nominal): 1.5mm Crush resistance (long term): 1000 N/10cm Δα< 0.05 dB reversible, no damage
Cable overal diameter (nominal): for 4 and   6 fibers = 7.5mm
for 8 and 12 fibers =  8.5mm
Impact resistance: 10 N.m, 3 impacts spaced, R=30min Δα< 0.05 dB reversible, no damage
Weight: for 4 and   6 fibers = 45 kg/Km
for 8 and 12 fibers = 55 kg/Km
Torsion: ± 180°C, 3 cycles, 50 N Δα< 0.05 dB reversible, no damage
    Bending (static): R = 10 x D, 5 turns, 3 cycles Δα< 0.05 dB reversible, no damage
    Repeated bending (dynamic): R = 15 x D, 100 N, 30 cycles Δα< 0.05 dB reversible, no damage
    Temperature cycling: from -25°C to +70°C Δα< 0.05 dB reversible, no damage
    Wather tightness:

3m cable, 1m water column, 24h

no water detected with UV light

 

Identification color coding  
Fiber colors per tube   
1

2

3 4 5 6 7 8 9 10 11 12
red Green Yellow Natural Brown Violet Grey Turquise White Pink Orange Blue

More information for single-mode optical fibers and multi-mode optical fibers can be found in the datasheet.